Motor hums but the shutter does not move
Often a failed capacitor on single-phase units, a sheared drive key, a stripped gear or a broken chain.
24/7 Emergency Response
Dublin & surrounding counties · 365 days a year
Motors & controls
A shutter that does nothing is not always a failed motor. Around half the 'motor faults' we attend turn out to be controls, limits or supply.
What this service covers
Motor and control faults are the largest single category of roller shutter breakdowns. The symptoms overlap — nothing happens, the door moves one way only, or the motor runs without the curtain moving — so proper diagnosis avoids replacing equipment that is still serviceable.
Access Opening Solutions repairs tube motors, side-drive units, gearboxes, control panels, key switches, remotes and safety devices on commercial and industrial doors across Dublin.
Tube and side-drive motors tested under load before any decision to replace is made.
Mechanical and electronic limits reset so the door stops correctly at both ends of travel.
Contactors, relays, inverters, push-button stations, key switches and emergency stops.
Re-pairing, replacement handsets, receiver faults and interference problems.
Safety edges, photocells and interlocks that are stopping the door or preventing it starting.
Common faults and warning signs
Often a failed capacitor on single-phase units, a sheared drive key, a stripped gear or a broken chain.
Frequently a limit, contactor or control fault rather than the motor itself.
Limits have drifted, or a safety device is intervening early.
Overload caused by binding guides, failed bearings or spring imbalance — resetting alone will not fix it.
Isolator, supply, emergency stop, safety edge circuit or control station failure.
Typical causes of failure
What to do immediately
How we diagnose the problem
Replacing components without establishing the cause is how doors end up failing twice. This is the sequence our engineers work through.
Supply and isolation are confirmed first, then the control circuit is tested step by step from the station to the contactor.
The motor is tested under load; a motor that runs freely off-load can still be failing.
Drive train components — key, coupling, chain, sprockets and gearbox — are inspected before condemning the motor.
Curtain balance and guide friction are checked so a replacement motor is not fitted into the same overload condition.
Repair or replace?
We recommend replacement only where continuing to repair would be unsafe, uneconomic or impossible because of part availability.
Premises we serve
Planned maintenance advice
Questions we are asked
Not necessarily. A humming motor is often a failed capacitor, a sheared key or a broken drive chain. We test before recommending replacement.
Yes. Handsets can usually be replaced and re-paired, or the receiver replaced where the original system is obsolete.
Repeated tripping normally means the motor is overloaded by a mechanical problem — binding guides, worn bearings or spring imbalance. That underlying cause needs to be corrected.
Yes, including modern control stations, safety devices and, where suitable, remote or key-switch operation.
24/7 Emergency Response
Describe exactly what the door does — or does not do — and we will bring the right equipment.
Or email info@accessopeningsolutions.com with photographs of the shutter and its location.